Rack Air Removal 208/230V 50/60 Hz NS VX Wide Kit
-
Air distribution systems for power dense racks and low pressure areas
-
Includes: Installation guide, Rack mounting brackets, User manual
Recommended replacement:
![Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 750mm enclosures.](http://www.apc.com/resource/images/products/200/0D4F4AB9-5056-9170-D35801CC5D962DDC_f_v_200x100.jpg)
Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 750mm enclosures.,
ACF402
ACF104BLK Features
Key Features
Input Connections
IEC 60320 C13, IEC 60320 C14
Rack Air Removal 208/230V 50/60 Hz NS VX Wide Kit
Air distribution systems for power dense racks and low pressure areas
Includes: Installation guide, Rack mounting brackets, User manual
-
Ducted Exhaust System
Removes hot air from the data center to prevent re-circulation and eliminate air mixing.
-
Power or Temperature Controlled Fans
Controls fan speed based on power input or exhaust temperature setpoint.
-
Redundancy
Systems can be configured to included an additional InRow cooling unit to provide N+1 or 2N redundancy.
Rack Air Distribution Features & Benefits
Agility
Easy to install
Innovative design allows for fast, easy installation by almost anybody.
Availability
Increases Airflow
Provides proper intake temperatures, increasing equipment life.
Product Distribution
United Arab Emirates, Afghanistan, Albania, Armenia, Angola, Argentina, Austria, Australia, Azerbaijan, Bosnia & Herzegovina, Belgium, Burkina Faso, Bulgaria, Bahrain, Burundi, Benin, Botswana, Belarus, Canada, Congo - Kinshasa, Switzerland, Côte d’Ivoire, Chile, Cameroon, China, Cyprus, Czechia, Djibouti, Denmark, Algeria, Estonia, Egypt, Eritrea, Spain, Ethiopia, Finland, Fiji, France, Gabon, United Kingdom, Georgia, French Guiana, Ghana, Gambia, Guadeloupe, Greece, Hong Kong SAR China, Croatia, Hungary, Indonesia, Ireland, Israel, India, Iraq, Iceland, Jordan, Kenya, Cambodia, South Korea, Kuwait, Kazakhstan, Lebanon, Liberia, Lithuania, Luxembourg, Latvia, Morocco, Madagascar, Mali, Myanmar (Burma), Mongolia, Martinique, Mauritania, Malta, Mauritius, Malawi, Malaysia, Mozambique, Namibia, Nigeria, Netherlands, Norway, New Zealand, Oman, Philippines, Pakistan, Poland, Portugal, Paraguay, Réunion, Romania, Rwanda, Saudi Arabia, Sweden, Singapore, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Suriname, Togo, Thailand, Tajikistan, Turkmenistan, Turkey, Tanzania, Ukraine, Uganda, United States, Uruguay, Uzbekistan, Vietnam, Yemen, Mayotte, South Africa, Zambia, Zimbabwe
Input
Input frequency
50/60 Hz
Number of Power Cords
2
Input Power
920 Watts
Physical
Maximum Height
1921MM, 192.1CM
Maximum Width
749MM, 74.9CM
Maximum Depth
178MM, 17.8CM
Net Weight
65.91KG
Color
Black
Conformance
Approvals
C-Tick, CE, cUL recognized, FCC part 15 class B, GS Mark, UL recognized, VDE
Standard warranty
2 years repair or replace
General
Air Flow
471.9lps