Rack PDU, Switched, 2U, 30A, 208V, (16)C13

Share:

Rack PDU, Switched, 2U, 30A, 208V, (16)C13

AP7911B

In stock
$1,040.00
Quantity

AP7911B 

Rack PDU, Switched, 2U, 30A, 208V, (16)C13

With Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on/off outlet level power cycling and sequencing control.

Includes : Documentation CD , Installation guide , Rack mounting brackets

  • Resettable circuit breakers
    Enables a quick recovery from overload events.

NetShelter Switched Rack PDUs Features & Benefits

  • Gigabit Ethernet Connectivity
    9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity.
  • Enhanced Cybersecurity
    9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind.
  • Network Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.
  • Multi-tier user access
    Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.
  • EcoStruxure IT Ready
    Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Outlet Level Grouping
    Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility.
  • Network Port Sharing
    Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series.
  • 1% Metering Accuracy
    Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.
  • C13/C15 and C19/C21 Hybrid Outlets
    Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.
  • 60C Operating Temperature
    All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).
  • High Retention Outlets
    With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.
  • Field-replaceable NMC
    Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.
  • Hydraulic Magnetic Circuit Breakers
    Provide increased availability by maintaining trip current over a wide temperature range.
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Product Distribution
Product Distribution

Antigua & Barbuda , Anguilla , Netherlands Antilles , Argentina , Barbados , Belgium , Bermuda , Bolivia , Brazil , Belize , Canada , Chile , China , Colombia , Costa Rica , Serbia and Montenegro , Dominican Republic , Ecuador , United Kingdom , Greece , Guatemala , Guyana , Honduras , Israel , Italy , Jamaica , Japan , Mexico , Nicaragua , Netherlands , Panama , Peru , Puerto Rico , Paraguay , Singapore , El Salvador , Turkey , Trinidad & Tobago , Taiwan , United States , Uruguay , Venezuela , U.S. Virgin Islands , South Africa

Print Technical Specification

Output

  • Nominal Output Voltage
    208V
  • Maximum Total Current Draw
    30
  • Output Connections
    (16) IEC 60320 C13 (Battery Backup)

Input

  • Nominal Input Voltage
    200V , 208V , 230V
  • Input frequency
    50/60 Hz
  • Input Connections
    NEMA L6-30P
  • Cord Length
    12.14ft ( 3.7meters )
  • Acceptable Input Voltage
    200 - 240VAC
  • Number of Power Cords
    1
  • Load Capacity
    4992VA
  • Maximum Input Current
    30A
  • Regulatory Derated Input Current (North America)
    24A

Physical

  • Maximum Height
    3.5inches ( 89MM , 8.9CM )
  • Maximum Width
    17.48inches ( 444MM , 44.4CM )
  • Maximum Depth
    10.0inches ( 254MM , 25.4CM )
  • Rack Height
    2U
  • Net Weight
    13.93lbs. ( 6.32KG )
  • Shipping weight
    18.43lbs. ( 8.36KG )
  • Shipping Height
    5.75inches ( 146MM , 14.6CM )
  • Shipping Width
    20.24inches ( 514MM , 51.4CM )
  • Shipping Depth
    20.24inches ( 514MM , 51.4CM )
  • Color
    Black

Environmental

  • Operating Temperature
    32 - 113 °F ( 0 - 45 °C )
  • Operating Relative Humidity
    0 - 95 %
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Storage Temperature
    -25 - 65 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0 - 50000ft ( 0 - 15240meters )

Conformance

  • Approvals
    CSA, cUL listed, FCC part 15 class A, ICES-003, Industry Canada, PSE, UL 60950, UL listed
  • Standard warranty
    2 years repair or replace
Manuals and Warranties
Title
Size
Updated On
PDF

Size

547KB

Updated On

2024-07-29

Release Notes for: AP7•••B and AP8••• series Rack Power Distribution Units and AP71••B Inline Current Meters
PDF

Size

6675KB

Updated On

2024-05-16

PDF

Size

523KB

Updated On

2024-02-07

Design/Configuration
Title
Size
Updated On
PDF

Size

192KB

Updated On

2021-04-26

Features and Specifications
Agency Approvals
Title
Size
Updated On
PDF

Size

360KB

Updated On

2024-02-29

PDF

Size

977KB

Updated On

2022-10-07

PDF

Size

709KB

Updated On

2022-10-07

PDF

Size

274KB

Updated On

2022-10-07

Quick Sales Reference Sheet
Title
Size
Updated On
PDF

Size

123KB

Updated On

2023-09-29

Reference the new features of the AP7000 Series "B" SKU PDUs which replaced the previous generation at the end of 2016.
Source

Size

4883KB

Updated On

2019-07-30

Reference the new features of the AP7000 Series "B" SKU PDUs which replaced the previous generation at the end of 2016.
Title
Size
Updated On
Power Distribution, Switched Rack PDU

Firmware Upgrades

InfraStruxure Manager
Part Number
Updated On

Part Number

AP9435

Updated On

2020-05-25

Category

Sub-Category


InfraStruXure® Manager Incident Management Module

Notification and event analysis for managing network-critical physical infrastructure (NCPI). Increase confidence of your NCPI availability by adding the Incident Management Module to your APC InfraStruXure® Manager. The added module enables quick and easy identification of the physical location and logical impact of a problem, and identifies the owner of the problem resolution. It helps establish and confirm a policy appropriate to your organization, ensuring the right people are notified for fast problem resolution, and prioritizes the urgency level of the incident accordingly. The Incident Management Module enables you to take proper corrective actions to return to the normal service level quickly, with minimal impact on business activity.

Warranty extension service pack, for accessories, 1yr, level 01

Get an extension of factory warranty coverage beyond the original factory warranty term for peace of mind and protection from failure

WBEXTWAR1YR-AC-03
$86.00

Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product