Trade-UPS For Edge Computing

Welcome to Trade-UPS

APC Trade-UPS is a 1-phase UPS program that offers new and existing customers the ability to trade in older battery backup units for the most up-to-date 1-phase power protection models at discounted prices.

More about the program Program rules
Trade-in UPS summary
Number of trade-ins:0
Trade-in VA total:0 VA
New trade-UPS VA range
Trade-UPS target VA range
0 VA 0 VA
min. max.
New UPS summary
Number of new UPS(s):0
New UPS VA total:0 VA

Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

AP7850B

In stock
$589.00
Quantity

AP7850B 

Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered rack Power Distribution Units (PDUs) provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.

Includes : Cord retention bracket(s) , Installation guide , Rack mounting brackets , Toolless mounting kit

  • Toolless Rack Mounting Capabilities
    Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.
  • Vertical Mounting Capabilities
    Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.

NetShelter Metered Rack PDUs Features & Benefits

  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Local Current Monitoring Display
    The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • 60C Operating Temperature
    All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).
  • Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Command Line Interface. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Product Distribution
Product Distribution

United Arab Emirates , Afghanistan , Antigua & Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Azerbaijan , Bosnia & Herzegovina , Barbados , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bermuda , Bolivia , Bahamas , Botswana , Belarus , Belize , Canada , Congo - Kinshasa , Switzerland , Côte d’Ivoire , Chile , Cameroon , China , Colombia , Costa Rica , Serbia and Montenegro , Cyprus , Czechia , Germany , Djibouti , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Eritrea , Spain , Ethiopia , Finland , Fiji , France , Gabon , United Kingdom , Grenada , Georgia , French Guiana , Ghana , Gambia , Guadeloupe , Greece , Guatemala , Guyana , Hong Kong SAR China , Honduras , Croatia , Haiti , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iceland , Italy , Jamaica , Jordan , Kenya , St. Kitts & Nevis , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , St. Lucia , Liberia , Lithuania , Luxembourg , Latvia , Morocco , Madagascar , North Macedonia , Mali , Myanmar (Burma) , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Malaysia , Mozambique , Namibia , Nigeria , Nicaragua , Netherlands , Norway , New Zealand , Oman , Panama , Peru , Philippines , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Réunion , Romania , Rwanda , Saudi Arabia , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Turks & Caicos Islands , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , Turkey , Trinidad & Tobago , Taiwan , Tanzania , Ukraine , Uganda , United States , Uruguay , Uzbekistan , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Output

  • Nominal Output Voltage
    230V
  • Overload Protection
    No
  • Maximum Total Current Draw
    10
  • Output Connections
    (16) IEC 60320 C13 (Battery Backup)

Input

  • Nominal Input Voltage
    200V , 208V , 230V
  • Input frequency
    47 - 63 Hz
  • Input Connections
    IEC 60320 C14
  • Cord Length
    10.01ft ( 3.1meters )
  • Acceptable Input Voltage
    200 - 250VAC
  • Number of Power Cords
    1
  • Load Capacity
    2300VA
  • Maximum Line Current
    10A

Physical

  • Maximum Height
    49.02inches ( 1245MM , 124.5CM )
  • Maximum Width
    2.2inches ( 56MM , 5.6CM )
  • Maximum Depth
    1.73inches ( 44MM , 4.4CM )
  • Net Weight
    6.77lbs. ( 3.07KG )
  • Shipping weight
    8.77lbs. ( 3.98KG )
  • Shipping Height
    84.02inches ( 2134MM , 213.4CM )
  • Shipping Width
    12.72inches ( 323MM , 32.3CM )
  • Shipping Depth
    15.24inches ( 387MM , 38.7CM )
  • Color
    Black

Environmental

  • Operating Temperature
    23 - 113 °F ( -5 - 45 °C )
  • Operating Relative Humidity
    5 - 95 %
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Storage Temperature
    -25 - 65 °C
  • Storage Relative Humidity
    5 - 95 %
  • Storage Elevation
    0 - 50000ft ( 0 - 15240meters )

Conformance

  • Approvals
    CE, GOST, VDE
  • Standard warranty
    2 years repair or replace
Manuals and Warranties
Title
Size
Updated On
PDF

Size

547KB

Updated On

2024-07-29

Release Notes for: AP7•••B and AP8••• series Rack Power Distribution Units and AP71••B Inline Current Meters
PDF

Size

6675KB

Updated On

2024-05-16

PDF

Size

523KB

Updated On

2024-02-07

PDF

Size

113KB

Updated On

2021-11-08

Release Notes for NetShelter Rack PDUs. AOS v704, rpdu2g v706,
PDF

Size

1572KB

Updated On

2018-06-19

Covers the function of the Device interface, the CLI, and the Web UI for both deployment and ongoing system monitoring
Design/Configuration
Title
Size
Updated On
PDF

Size

935KB

Updated On

2022-02-18

Features and Specifications
Agency Approvals
Title
Size
Updated On
PDF

Size

360KB

Updated On

2024-02-29

PDF

Size

61KB

Updated On

2024-02-22

SDOC for CMIM Compliance for Morocco_AP78XX Series PDUs
PDF

Size

273KB

Updated On

2023-09-07

PDF

Size

177KB

Updated On

2022-10-07

PDF

Size

766KB

Updated On

2022-10-07

PDF

Size

274KB

Updated On

2022-10-07

PDF

Size

91KB

Updated On

2022-10-07

EU DoC for LV, EMC, and RoHS Directives
Quick Sales Reference Sheet
Title
Size
Updated On
PDF

Size

123KB

Updated On

2023-09-29

Reference the new features of the AP7000 Series "B" SKU PDUs which replaced the previous generation at the end of 2016.
Source

Size

4883KB

Updated On

2019-07-30

Reference the new features of the AP7000 Series "B" SKU PDUs which replaced the previous generation at the end of 2016.
Title
Size
Updated On
Power Distribution, Metered Rack PDU

Category

Sub-Category


NetShelter Zero U Accessory Mounting Bracket

Installs in various locations within the enclosure; for example, on the vertical mounting flanges and on the vertical 0U accessory channels. Provides mounting options for Rack PDUs and other small accessories.

AR7711
$90.00
Warranty extension service pack, for accessories, 1yr, level 01

Get an extension of factory warranty coverage beyond the original factory warranty term for peace of mind and protection from failure

WBEXTWAR1YR-AC-02
$54.00

Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product