Trade-UPS For Edge Computing

Welcome to Trade-UPS

APC Trade-UPS is a 1-phase UPS program that offers new and existing customers the ability to trade in older battery backup units for the most up-to-date 1-phase power protection models at discounted prices.

More about the program Program rules
Trade-in UPS summary
Number of trade-ins:0
Trade-in VA total:0 VA
New trade-UPS VA range
Trade-UPS target VA range
0 VA 0 VA
min. max.
New UPS summary
Number of new UPS(s):0
New UPS VA total:0 VA

Rack PDU, Metered, 2U, 30A, 208V, (12) C13s & (4) C19

Share:

Rack PDU, Metered, 2U, 30A, 208V, (12) C13s & (4) C19

AP7811B

In stock
$833.00
Quantity

AP7811B 

Rack PDU, Metered, 2U, 30A, 208V, (12) C13s & (4) C19

Metered rack Power Distribution Units (PDUs) provide real-time remote monitoring of connected loads. User-defined alarms warn of potential circuit overloads before critical IT failures occur.

Includes : Cord retention bracket(s) , Installation guide , Rack mounting brackets , User manual

  • Resettable circuit breakers
    Enables a quick recovery from overload events.

NetShelter Metered Rack PDUs Features & Benefits

  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Command Line Interface. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • 60C Operating Temperature
    All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Local Current Monitoring Display
    The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Product Distribution
Product Distribution

Antigua & Barbuda , Anguilla , Netherlands Antilles , Barbados , Belgium , Bermuda , Bolivia , Brazil , Bahamas , Belize , Canada , Colombia , Costa Rica , Serbia and Montenegro , Dominica , Dominican Republic , Ecuador , Grenada , Guadeloupe , Guatemala , Guyana , Honduras , Croatia , Haiti , Israel , Italy , Jamaica , Japan , St. Kitts & Nevis , Martinique , Nicaragua , Netherlands , Panama , Peru , Puerto Rico , Slovenia , El Salvador , Turks & Caicos Islands , Turkey , Trinidad & Tobago , Taiwan , United States , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands

Print Technical Specification

Output

  • Nominal Output Voltage
    208V
  • Overload Protection
    Yes
  • Maximum Total Current Draw
    24
  • Output Connections
    (12) IEC 60320 C13 (Battery Backup)
    (4) IEC 60320 C19 (Battery Backup)

Input

  • Nominal Input Voltage
    200V , 208V , 230V
  • Input frequency
    50/60 Hz
  • Input Connections
    NEMA L6-30P
  • Cord Length
    12.14ft ( 3.7meters )
  • Number of Power Cords
    1
  • Load Capacity
    4992VA
  • Maximum Input Current
    30A
  • Regulatory Derated Input Current (North America)
    24A

Physical

  • Maximum Height
    3.46inches ( 88MM , 8.8CM )
  • Maximum Width
    17.48inches ( 444MM , 44.4CM )
  • Maximum Depth
    4.41inches ( 112MM , 11.2CM )
  • Rack Height
    2U
  • Net Weight
    7.41lbs. ( 3.36KG )
  • Shipping weight
    11.95lbs. ( 5.42KG )
  • Shipping Height
    5.51inches ( 140MM , 14.0CM )
  • Shipping Width
    14.49inches ( 368MM , 36.8CM )
  • Shipping Depth
    20.0inches ( 508MM , 50.8CM )

Environmental

  • Operating Temperature
    23 - 113 °F ( -5 - 45 °C )
  • Operating Relative Humidity
    5 - 95 %
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Storage Temperature
    -25 - 65 °C
  • Storage Relative Humidity
    5 - 95 %
  • Storage Elevation
    0 - 50000ft ( 0 - 15240meters )

Conformance

  • Approvals
    CSA, cUL listed, FCC part 15 class A, ICES-003, PSE, UL 60950, UL listed
  • Standard warranty
    2 years repair or replace
Manuals and Warranties
Title
Size
Updated On
PDF

Size

547KB

Updated On

2024-07-01

Release Notes for: AP7•••B and AP8••• series Rack Power Distribution Units and AP71••B Inline Current Meters
PDF

Size

6675KB

Updated On

2024-05-16

PDF

Size

523KB

Updated On

2022-09-14

PDF

Size

113KB

Updated On

2021-11-08

Release Notes for NetShelter Rack PDUs. AOS v704, rpdu2g v706,
PDF

Size

1572KB

Updated On

2018-06-19

Covers the function of the Device interface, the CLI, and the Web UI for both deployment and ongoing system monitoring
Design/Configuration
Title
Size
Updated On
PDF

Size

135KB

Updated On

2023-09-29

Features and Specifications
Agency Approvals
Title
Size
Updated On
PDF

Size

360KB

Updated On

2024-02-29

PDF

Size

977KB

Updated On

2022-10-07

PDF

Size

274KB

Updated On

2022-10-07

PDF

Size

145KB

Updated On

2022-10-07

DENAN Statement of Conformity Assessment
Environmental Profile
Title
Size
Updated On
PDF

Size

429KB

Updated On

2024-06-17

Quick Sales Reference Sheet
Title
Size
Updated On
PDF

Size

123KB

Updated On

2023-09-29

Reference the new features of the AP7000 Series "B" SKU PDUs which replaced the previous generation at the end of 2016.
Source

Size

4883KB

Updated On

2019-07-30

Reference the new features of the AP7000 Series "B" SKU PDUs which replaced the previous generation at the end of 2016.
Title
Size
Updated On
Power Distribution, Metered Rack PDU

Firmware Upgrades

InfraStruxure Manager
Part Number
Updated On

Part Number

AP9435

Updated On

2020-05-25

Category

Sub-Category


Warranty extension service pack, for accessories, 1yr, level 07

Get an extension of factory warranty coverage beyond the original factory warranty term for peace of mind and protection from failure

WBEXTWAR1YR-AC-02
$51.00
InfraStruXure® Manager Incident Management Module

Notification and event analysis for managing network-critical physical infrastructure (NCPI). Increase confidence of your NCPI availability by adding the Incident Management Module to your APC InfraStruXure® Manager. The added module enables quick and easy identification of the physical location and logical impact of a problem, and identifies the owner of the problem resolution. It helps establish and confirm a policy appropriate to your organization, ensuring the right people are notified for fast problem resolution, and prioritizes the urgency level of the incident accordingly. The Incident Management Module enables you to take proper corrective actions to return to the normal service level quickly, with minimal impact on business activity.


Show results per page