Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19

Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19

AP8888

In stock
$2,165.00
Quantity

AP8888 

Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19

APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Includes : Installation guide , Rack mounting brackets , Safety guide , Serial configuration cable

NetShelter Metered Rack PDUs Features & Benefits

  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Local Current Monitoring Display
    The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • 60C Operating Temperature
    All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).
  • Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Command Line Interface. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Product Distribution
Product Distribution

Belgium , Canada , Switzerland , China , Serbia and Montenegro , Greece , Israel , Italy , Morocco , Netherlands , Norway , Portugal , United States

Print Technical Specification

Output

  • Nominal Output Voltage
    240V
  • Overload Protection
    Yes
  • Maximum Total Current Draw
    32
  • Output Connections
    (12) IEC 60320 C19 (Battery Backup)
    (30) IEC 60320 C13 (Battery Backup)

Input

  • Nominal Input Voltage
    400V 3PH
  • Input frequency
    50/60 Hz
  • Input Connections
    IEC 60309 60 A 3P + N + E
  • Cord Length
    5.91ft ( 1.8meters )
  • Number of Power Cords
    1
  • Load Capacity
    23000VA
  • Maximum Input Current
    40A
  • Regulatory Derated Input Current (North America)
    32A

Physical

  • Maximum Height
    72.01inches ( 1829MM , 182.9CM )
  • Maximum Width
    2.2inches ( 56MM , 5.6CM )
  • Maximum Depth
    2.01inches ( 51MM , 5.1CM )
  • Net Weight
    22.27lbs. ( 10.1KG )
  • Shipping weight
    30.97lbs. ( 14.05KG )
  • Shipping Height
    84.61inches ( 2149MM , 214.9CM )
  • Shipping Width
    4.41inches ( 112MM , 11.2CM )
  • Shipping Depth
    8.7inches ( 221MM , 22.1CM )
  • Color
    Black

Environmental

  • Operating Temperature
    23 - 140 °F ( -5 - 60 °C )
  • Operating Relative Humidity
    5 - 95 %
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Storage Temperature
    -25 - 65 °C
  • Storage Relative Humidity
    5 - 95 %
  • Storage Elevation
    0 - 50000ft ( 0 - 15240meters )

Conformance

  • Approvals
    cUL listed, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003, UL listed, VCCI class A
  • Standard warranty
    2 years repair or replace
Manuals and Warranties
Title
Size
Updated On
PDF

Size

547KB

Updated On

2024-07-29

Release Notes for: AP7•••B and AP8••• series Rack Power Distribution Units and AP71••B Inline Current Meters
PDF

Size

5953KB

Updated On

2024-05-16

PDF

Size

1939KB

Updated On

2024-05-07

Provides the safety information for installation and operation of the Rack PDU.
PDF

Size

122KB

Updated On

2024-02-21

PDF

Size

1689KB

Updated On

2024-02-07

Includes multi-language installation instructions and DHCP network information for MPO (managed per outlet AP86xx) Rack Power Distribution Units
PDF

Size

58KB

Updated On

2023-10-04

Release Notes for AP88XX Metered Rack PDUs and AP89xx/AP86xx Switched Rack PDUs for Application Module v6.4.0, APC OS (AOS) v6.4.0, and the APC PowerNet MIB v415
PDF

Size

113KB

Updated On

2021-11-08

Release Notes for NetShelter Rack PDUs. AOS v704, rpdu2g v706,
Catalogs
Title
Size
Updated On
PDF

Size

7075KB

Updated On

2024-11-04

Brochure including Basic, Metered, Switched, and Metered by Outlet Rack PDUs product features and specifications
PDF

Size

48KB

Updated On

2023-10-04

Chart that specifies the APC Modular Power Distribution Units that support the installation of APC 208V & 415V Power Distribution Modules and specifies compatible APC Rack PDUs for each PDM.
Design/Configuration
Title
Size
Updated On
PDF

Size

1533KB

Updated On

2023-10-04

Includes an illustration with a description of product features as well as electrical, physical, environmental, and compliance specifications.
Agency Approvals
Title
Size
Updated On
PDF

Size

23KB

Updated On

2024-02-22

VCCI for Metered Rack PDU
PDF

Size

1067KB

Updated On

2024-02-21

Stencils
Title
Size
Updated On
Source

Size

893KB

Updated On

2021-08-27

Rack PDU, Metered
PDF

Size

895KB

Updated On

2019-07-30

Rack PDU, Metered
Environmental Profile
Title
Size
Updated On
PDF

Size

429KB

Updated On

2024-06-17

Title
Size
Updated On
Power Distribution, Metered Rack PDU

Category

Sub-Category


Power Cord Kit (6 ea), Locking, C13 to C14, 1.8M (6ft), North America, Blue

Wide selection of Rack PDU power cords for a variety of IT equipment.

AP8706S-NAX590
$135.00
Power Cord Kit (6 ea), Locking, C19 to C20, 1.8m, Blue

Wide selection of Rack PDU power cords for a variety of IT equipment.

AP8716SX593
$198.00
Power Cord Kit (6 ea), Locking, C13 to C14 (90 Degree), 1.8m, North America

Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this exclusive easy-to-use cord retention method. While these cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled only when used with APC AP8000 series Rack PDUs or IT equipment with built-in locking receptacles. These locking connectors reduce the probability of accidentally disconnecting cords and dropping loads.

AP8706R-NA
$136.00
Power Cord Kit (6 ea), Locking, C13 to C14, 1.2m, North America

Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this exclusive easy-to-use cord retention method. While these cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled only when used with APC AP8000 series Rack PDUs or IT equipment with built-in locking receptacles. These locking connectors reduce the probability of accidentally disconnecting cords and dropping loads.

AP8704S-NA
$97.00
Power Cord Kit (6 ea), Locking, C13 TO C14 (90 Degree), 0.6m, North America

Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this exclusive easy-to-use cord retention method. While these cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled only when used with APC AP8000 series Rack PDUs or IT equipment with built-in locking receptacles. These locking connectors reduce the probability of accidentally disconnecting cords and dropping loads.

AP8702R-NA
$59.00
Rack PDU Red label kit (Quantity 10 units)

Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.

AP8000RED
$64.00
Power Cord Kit (6 EA), Locking, C19 TO C20, 0.6M (2FT), Red

Wide selection of Rack PDU power cords for a variety of IT equipment.

AP8712SX340
$122.00
Power Cord Kit (6 EA), Locking, C19 TO C20, 1.2M (4FT), Red

Wide selection of Rack PDU power cords for a variety of IT equipment.

AP8714SX340
$162.00
Power Cord Kit (6 ea), Locking, C13 to C14, 0.6m (2ft), North America, Blue

Wide selection of Rack PDU power cords for a variety of IT equipment.

AP8702S-NAX590
$59.00
Power Cord Kit (6 ea), Locking, C19 to C20, 0.6m (2ft), Blue

Wide selection of Rack PDU power cords for a variety of IT equipment.

AP8712SX590
$122.00