Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 750mm enclosures.

Share:

Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 750mm enclosures.

ACF402

$2,860.00
Quantity

ACF402 

Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 750mm enclosures.

High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, returns the warm air to the plenum and eliminates hot spots from the data center. Through automatic fan speed control based upon temperature, the fans will self-adjust for optimal performance. With a unit-mounted LCD display, users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control. This space-saving solution mounts to the back of either the NetShelter SX or VX enclosure, requiring zero U space.

Includes : Documentation CD , Installation guide , Operations and maintenance manual

  • Adjustable mounting frame
    The frame can mount on Netshelter SX or VX enclosures and extends to accommodate 42U, 47U or 48U rack heights.
  • Ducted Exhaust System
    Removes hot air from the data center to prevent re-circulation and eliminate air mixing.
  • Fault-tolerant fan system
    In the event of a fan failure, the remaining fan(s) will continue to operate.
  • Field replaceable components
    Fans and electronics module can be readily replaced without uninstalling the unit.
  • Increased capacity
    Higher rate of heat removal allows more equipment to be installed in each rack.
  • LCD display
    Manage the UPS locally through a text-based display that allows quick diagnosis via stored alarm conditions and events.
  • Network interface
    Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
  • Temperature monitoring
    Changes in temperature are reported via the user interface or e-mail.

Rack Air Distribution Features & Benefits

  • Increases Airflow
    Provides proper intake temperatures, increasing equipment life.
  • Easy to install
    Innovative design allows for fast, easy installation by almost anybody.
Product Distribution
Product Distribution

United Arab Emirates , Afghanistan , Antigua & Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Austria , Australia , Azerbaijan , Bosnia & Herzegovina , Barbados , Belgium , Burkina Faso , Bulgaria , Bahrain , Burundi , Benin , Bermuda , Bolivia , Brazil , Bahamas , Botswana , Belarus , Belize , Canada , Congo - Kinshasa , Switzerland , Côte d’Ivoire , Chile , Cameroon , China , Colombia , Costa Rica , Serbia and Montenegro , Cyprus , Czechia , Germany , Djibouti , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Eritrea , Spain , Ethiopia , Finland , Fiji , France , Gabon , United Kingdom , Grenada , Georgia , French Guiana , Ghana , Gambia , Guadeloupe , Greece , Guatemala , Guyana , Hong Kong SAR China , Honduras , Croatia , Haiti , Hungary , Indonesia , Ireland , Israel , India , Iraq , Iceland , Italy , Jamaica , Jordan , Japan , Kenya , St. Kitts & Nevis , South Korea , Kuwait , Cayman Islands , Kazakhstan , Lebanon , St. Lucia , Liberia , Lithuania , Luxembourg , Latvia , Morocco , Madagascar , North Macedonia , Mali , Myanmar (Burma) , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mexico , Malaysia , Mozambique , Namibia , Nigeria , Nicaragua , Netherlands , Norway , New Zealand , Oman , Panama , Peru , Philippines , Pakistan , Poland , Puerto Rico , Portugal , Paraguay , Réunion , Romania , Rwanda , Saudi Arabia , Sweden , Singapore , Slovenia , Slovakia , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Turks & Caicos Islands , Togo , Thailand , Tajikistan , Turkmenistan , Tunisia , Turkey , Trinidad & Tobago , Taiwan , Tanzania , Ukraine , Uganda , United States , Uruguay , Uzbekistan , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , Yemen , Mayotte , South Africa , Zambia , Zimbabwe

Print Technical Specification

Input

  • Input frequency
    50/60 Hz
  • Input Connections
    IEC 60320 C14, NEMA 5-15P
  • Number of Power Cords
    2
  • Input Power
    1200 Watts

Communications & Management

  • Control panel
    Multifunction LCD status and control console

Physical

  • Maximum Height
    75.51inches ( 1918MM , 191.8CM )
  • Maximum Width
    29.02inches ( 737MM , 73.7CM )
  • Maximum Depth
    10.0inches ( 254MM , 25.4CM )
  • Net Weight
    170.35lbs. ( 77.27KG )
  • Shipping weight
    222.47lbs. ( 100.91KG )
  • Color
    Black

Environmental

  • Operating Temperature
    32 - 122 °F ( 0 - 50 °C )
  • Operating Relative Humidity
    0 - 95 %
  • Storage Temperature
    0 - 50 °C
  • Storage Relative Humidity
    0 - 95 %
  • Storage Elevation
    0 - 15000ft ( 0 - 4572meters )
  • Audible noise at 1 meter from surface of unit
    79.0dBA

Conformance

  • Approvals
    CE, cUL listed, EN 55022 class A, EN 55024, FCC part 15 class A, ICES-003, IEC 61000-3-2, IEC 61000-3-3, UL listed, VDE
  • Standard warranty
    1 year (parts only)

Sustainable Offer Status

  • RoHS
    Compliant

General

  • Air Discharge Patterns
    Ducted, Upflow
  • Air Flow
    1600.0CFM ( 755.1lps )
Manuals and Warranties
Title
Size
Updated On
PDF

Size

61KB

Updated On

2023-09-29

PDF

Size

1554KB

Updated On

2023-09-29

PDF

Size

129KB

Updated On

2023-09-29

Release Notes
Agency Approvals
Title
Size
Updated On
Title
Size
Updated On
Cooling Solutions, Air Distribution, Rack Air Distribution
CAD Source File
6544KB
2023-10-04

Category

Sub-Category


APC Symmetra LX module CTO kit- XR 9 Frame

Accessory solutions to tailor the Symmetra to meet your specific needs

APC NetShelter Cable Management, Vertical Cable Manager, Cable Fall (radius drop), for for NetShelter Racks, and Cable Ladders, Set of 2

Cable Fall (radius drop) provides a proper bend radius for cabling routed into/out of enclosures or overhead cable management systems. Cable fall attaches in multiple locations including the enclosure roof holes, open frame rack sides, vertical cable manager openings and rungs of overhead cable ladder systems. Secure cabling in place using slots in the accessory and hook-and-loop fasteners straps (AR8621 not provided).

AR8654
$110.00
Custom Rack Power Distribution

Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.

APC Symmetra LX module CTO kit- XR3 Frame

Accessory solutions to tailor the Symmetra to meet your specific needs

APC NetShelter Cable Management, Vertical Cable Manager, Cable Retainer, for NetShelter SX 750mm W, Set of 6, 109 x 13 x 23 mm

Snap-on hinge covers conceal cables for a clean, professional look and easy access.

AR7582A
$47.00
Rack PDU, Basic, Zero U, 16A, 208/230V, (15) C13

Reliable rack power distribution

AP9572
$247.00
Rack PDU, Basic, 1U, 30A, 208V, (4) C19s

Reliable rack power distribution

AP9570
$280.00
Rack PDU 2G, Metered-by-Outlet, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19

APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

AP8481
$1,935.00
Rack PDU, Basic, 0U/1U, 208V, 30A, (4) C19

Reliable rack power distribution

AP6031A
$198.00
Fixed Shelf - 250lbs/114kg, Black

Fixed shelf to enable the mounting of tower units, monitors, and other equipment into the rack environment.

AR8122BLK
$113.00

Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product