Trade-UPS For Edge Computing

Welcome to Trade-UPS

APC Trade-UPS is a 1-phase UPS program that offers new and existing customers the ability to trade in older battery backup units for the most up-to-date 1-phase power protection models at discounted prices.

More about the program Program rules
Trade-in UPS summary
Number of trade-ins:0
Trade-in VA total:0 VA
New trade-UPS VA range
Trade-UPS target VA range
0 VA 0 VA
min. max.
New UPS summary
Number of new UPS(s):0
New UPS VA total:0 VA

Prefabricated Data Center 2000kW Power Module with Galaxy VX

Prefabricated Data Center 2000kW Power Module with Galaxy VX

PFMPE2000NAVX

Prefabricated Data Center 2000kW Power Module with Galaxy VX

null

Call for Availability
800-800-4272

Power Module Features & Benefits

  • Simple and Fast Deployment
    Prefabricated Data Center Modules arrive on site ready to deploy which significantly reduces installation time and cost.
  • Scalable and Flexible
    Prefabricated modules inherently allow for scalable growth of IT infrastructure and the flexibility to adjust the design and size of future phases of deployment. Capital investments can be deferred, improving cash flow.
  • Pre-engineered and Factory Assembled
    Prefabricated Modules are designed and built to precise specifications in a controlled factory environment and utilize DCIM software which results in improved reliability and a more predictably performing data center.
Product Distribution
Product Distribution

United States

Print Technical Specification

Output

  • Max Configurable Power (Watts)
    2.0MWatts / 0VA
  • Nominal Output Voltage
    480V 3PH
  • Output Frequency (sync to mains)
    60 Hz Sync to mains
  • Other Output Voltages
    480
  • Load Crest Factor
    3 with THC <5%
  • Waveform type
    Sine wave
  • Bypass
    Built-in maintenance bypass

Input

  • Nominal Input Voltage
    480V 3PH
  • Input Connections
    Hard wire 5-wire (3P + N + E)

Batteries & Runtime

  • Battery type
    Li-Ion (Lithium-Ion), VRLA
  • Replacement battery cartridge note
    VRLA type battery or Lithium Ion battery system options

Communications & Management

  • Emergency Power Off (EPO)
    Optional

Physical

  • Maximum Height
    0.48inches ( 12MM , 1.23CM )
  • Maximum Width
    145.67inches ( 3700MM , 370.0CM )
  • Maximum Depth
    624.02inches ( 15850MM , 1585.0CM )
  • Net Weight
    93799.81lbs. ( 42546.93KG )

Environmental

  • Operating Temperature
    -13 - 104 °F ( -25 - 40 °C )
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Audible noise at 1 meter from surface of unit
    85.0dBA
  • Protection Class
    IP5X

Conformance

  • Approvals
    UL
Brochure
Title
Size
Updated On
PDF

Size

511KB

Updated On

2023-09-29

Data Sheet for 2MW Prefabricated Data Center Power Enclosure NAM Version
Title
Size
Updated On
Mechanical Assembly Drawing Package for the 2MW Power Enclosure, NAM 480V
2MW NAM 480V Power Enclosure with 2 x Galaxy VX, Electrical One line