Trade-UPS For Edge Computing

Welcome to Trade-UPS

APC Trade-UPS is a 1-phase UPS program that offers new and existing customers the ability to trade in older battery backup units for the most up-to-date 1-phase power protection models at discounted prices.

More about the program Program rules
Trade-in UPS summary
Number of trade-ins:0
Trade-in VA total:0 VA
New trade-UPS VA range
Trade-UPS target VA range
0 VA 0 VA
min. max.
New UPS summary
Number of new UPS(s):0
New UPS VA total:0 VA

InRow RD, 600mm, Air Cooled, 200-240V, 50/60Hz

Share:

InRow RD, 600mm, Air Cooled, 200-240V, 50/60Hz

ACRD500

InRow RD, 600mm, Air Cooled, 200-240V, 50/60Hz
Discontinued

Uniflair Direct Expansion InRow Cooling Features & Benefits

  • Rack inlet temperature control
    Reduces the risk of hot spots at the rack level
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Scalable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Real-Time capacity monitoring
    Real-time display of current and available cooling.
  • Microprocessor controller
    Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Product Distribution
Product Distribution

Antigua & Barbuda , Anguilla , Netherlands Antilles , Barbados , Bermuda , Bolivia , Belize , Canada , Colombia , Costa Rica , Dominican Republic , Ecuador , Greece , Guatemala , Guyana , Honduras , Italy , Jamaica , South Korea , Cayman Islands , Morocco , Mexico , Nicaragua , Netherlands , Panama , Peru , Philippines , Puerto Rico , El Salvador , Trinidad & Tobago , Taiwan , United States , Venezuela , U.S. Virgin Islands

Print Technical Specification

Input

  • Input frequency
    50/60 Hz
  • Input Connections
    Hard wire 4-wire (3P + E)

Communications & Management

  • Control panel
    Multifunction LCD status and control console

Physical

  • Maximum Height
    78.39inches ( 1991MM , 199.1CM )
  • Maximum Width
    23.62inches ( 600MM , 60.0CM )
  • Maximum Depth
    42.13inches ( 1070MM , 107.0CM )
  • Rack Height
    42U
  • Net Weight
    809.69lbs. ( 367.27KG )
  • Shipping weight
    946.99lbs. ( 429.55KG )
  • Shipping Height
    85.28inches ( 2166MM , 216.6CM )
  • Shipping Width
    44.76inches ( 1137MM , 113.7CM )
  • Shipping Depth
    33.46inches ( 850MM , 85.0CM )
  • Color
    Black

Conformance

  • Approvals
    CE, cUL listed, Industry Canada, UL listed, VDE
  • Standard warranty
    1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

General

  • Air Flow
    4600.1CFM ( 2171.0lps )
  • Compressor Type
    Reciprocating
  • Condensate Pump Capacity
    7.9gal/hour ( 0.01lps )
Manuals and Warranties
Title
Size
Updated On
PDF

Size

1055KB

Updated On

2023-10-04

PDF

Size

163KB

Updated On

2018-06-12

Release Notes
Stencils
Title
Size
Updated On
PDF

Size

235KB

Updated On

2016-12-16

Cooling Solutions
Title
Size
Updated On
Cooling Solutions, InRow Direct Expansion, Package
Cooling Solutions, Chillers & Heat Rejection, Condensers
CAD Source File
418KB
2023-10-04

BIM Models, Cooling Solutions, InRow RD

Category

Sub-Category


Custom quoted service contract

An APC factory trained technician will arrive on site to diagnose or repair your APC equipment

Start-Up Service 7X24

A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution

Scheduling Upgrade to 7X24 for (1) Existing Cooling Assembly Service

A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution

Scheduled Air Assembly Service 5X8 for InRow RP DX units

A set of service options designed to deliver the vital resources, expertise, and tools needed to quickly and efficiently implement your APC by Schneider Electric solution


Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product