Condenser, 38kW, 95F(35C,460V/3, 60Hz

Share:

Condenser, 38kW, 95F(35C,460V/3, 60Hz

ACCD75230

Condenser, 38kW, 95F(35C,460V/3, 60Hz

null

Call for Availability
800-800-4272

ACCD75230 

Condenser, 38kW, 95F(35C,460V/3, 60Hz

  • Direct drive motors
    Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.

Uniflair Direct Expansion InRow Cooling Features & Benefits

  • Rack inlet temperature control
    Reduces the risk of hot spots at the rack level
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Scalable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Real-Time capacity monitoring
    Real-time display of current and available cooling.
  • Microprocessor controller
    Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Product Distribution
Product Distribution

Afghanistan , Antigua & Barbuda , Anguilla , Albania , Armenia , Netherlands Antilles , Angola , Argentina , Azerbaijan , Bosnia & Herzegovina , Barbados , Bangladesh , Burkina Faso , Bahrain , Burundi , Benin , Bermuda , Bolivia , Brazil , Bahamas , Botswana , Belarus , Belize , Canada , Congo - Kinshasa , Côte d’Ivoire , Cameroon , Colombia , Costa Rica , Serbia and Montenegro , Cyprus , Germany , Djibouti , Dominica , Dominican Republic , Ecuador , Eritrea , Ethiopia , Fiji , Gabon , Grenada , Georgia , French Guiana , Ghana , Gambia , Guadeloupe , Guatemala , Guyana , Honduras , Haiti , Iraq , Iceland , Jamaica , Jordan , Kenya , Cambodia , St. Kitts & Nevis , Kuwait , Cayman Islands , Lebanon , St. Lucia , Sri Lanka , Liberia , Luxembourg , Libya , Madagascar , Mali , Myanmar (Burma) , Mongolia , Martinique , Mauritania , Malta , Mauritius , Malawi , Mozambique , Namibia , Nicaragua , Oman , Panama , Peru , Pakistan , Puerto Rico , Paraguay , Qatar , Réunion , Rwanda , Sierra Leone , Senegal , Somalia , Suriname , El Salvador , Syria , Turks & Caicos Islands , Togo , Tajikistan , Turkmenistan , Trinidad & Tobago , Tanzania , Uganda , United States , Uruguay , Uzbekistan , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands , Yemen , Mayotte , Zambia , Zimbabwe

Print Technical Specification

Input

  • Input frequency
    60 Hz
  • Input Power
    3190 Watts
  • Maximum Overcurrent Protection
    15.0A
  • Minimum Circuit Amp Capacity
    8.0

Physical

  • Maximum Height
    32.44inches ( 824MM , 82.4CM )
  • Maximum Width
    38.46inches ( 977MM , 97.7CM )
  • Net Length
    10.33ft ( 3.2meters )
  • Maximum Depth
    124.06inches ( 3151MM , 315.1CM )
  • Net Weight
    479.99lbs. ( 217.72KG )
  • Shipping weight
    600.01lbs. ( 272.16KG )
  • Shipping Height
    35.0inches ( 889MM , 88.9CM )
  • Shipping Width
    130.0inches ( 3302MM , 330.2CM )
  • Shipping Depth
    42.99inches ( 1092MM , 109.2CM )

Environmental

  • Operating Temperature
    -4 - 122 °F ( -20 - 50 °C )
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Audible noise at 1 meter from surface of unit
    64.5dBA

Conformance

  • Approvals
    ETL
  • Standard warranty
    1 year (parts only)

Sustainable Offer Status

  • RoHS
    Compliant

General

  • Air Discharge Patterns
    Horizontal, Upflow
  • Air Flow
    16045.0CFM ( 7572.4lps )
  • Amp Draw In-Rush
    6.0A
  • Return Diameter
    0.87inches ( 22.0MM )
Design/Configuration
Title
Size
Updated On
PDF

Size

4538KB

Updated On

2023-10-04

InRow DX Gen 2 Technical Specifications
Title
Size
Updated On
Cooling Solutions, Chillers & Heat Rejection, Condensers
CAD Source File
8179KB
2023-10-04