Trade-UPS For Edge Computing

Welcome to Trade-UPS

APC Trade-UPS is a 1-phase UPS program that offers new and existing customers the ability to trade in older battery backup units for the most up-to-date 1-phase power protection models at discounted prices.

More about the program Program rules
Trade-in UPS summary
Number of trade-ins:0
Trade-in VA total:0 VA
New trade-UPS VA range
Trade-UPS target VA range
0 VA 0 VA
min. max.
New UPS summary
Number of new UPS(s):0
New UPS VA total:0 VA

Condenser 1x1 Build to Order, 38kW, 95F, 208-230V/3, 60Hz (qsce54076)

Share:

Condenser 1x1 Build to Order, 38kW, 95F, 208-230V/3, 60Hz (qsce54076)

ACCD75234

Condenser 1x1 Build to Order, 38kW, 95F, 208-230V/3, 60Hz (qsce54076)

null

Call for Availability
800-800-4272

ACCD75234 

Condenser 1x1 Build to Order, 38kW, 95F, 208-230V/3, 60Hz (qsce54076)

  • Direct drive motors
    Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.

Uniflair Direct Expansion InRow Cooling Features & Benefits

  • Rack inlet temperature control
    Reduces the risk of hot spots at the rack level
  • Predictable cooling
    Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
  • Active response controls
    Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Modular design
    Modular design provides scalable solutions to add cooling as demand increases.
  • Scalable densities
    Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
  • Easy service access
    Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Real-Time capacity monitoring
    Real-time display of current and available cooling.
  • Microprocessor controller
    Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
  • Building management system integration
    Send alarms and data points allowing you to manage critical building infrastructure from a single system.
  • Variable speed fans
    Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Row-based architecture
    Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Product Distribution
Product Distribution

Antigua & Barbuda , Anguilla , Netherlands Antilles , Argentina , Barbados , Bermuda , Bolivia , Bahamas , Belize , Canada , Chile , Colombia , Costa Rica , Serbia and Montenegro , Dominica , Dominican Republic , Ecuador , Grenada , French Guiana , Guadeloupe , Guatemala , Guyana , Honduras , Haiti , Jamaica , St. Kitts & Nevis , South Korea , St. Lucia , Madagascar , Martinique , Mauritius , Mexico , Nicaragua , Panama , Peru , Puerto Rico , Paraguay , Réunion , El Salvador , Turks & Caicos Islands , Trinidad & Tobago , United States , Uruguay , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands , Mayotte

Print Technical Specification

Input

  • Input frequency
    60 Hz
  • Input Power
    1450 Watts
  • Maximum Overcurrent Protection
    15.0A
  • Minimum Circuit Amp Capacity
    9.0

Physical

  • Maximum Height
    54.61inches ( 1387MM , 138.7CM )
  • Maximum Width
    48.94inches ( 1243MM , 124.3CM )
  • Net Length
    6.73ft ( 2.1meters )
  • Maximum Depth
    80.91inches ( 2055MM , 205.5CM )
  • Net Weight
    551.0lbs. ( 249.93KG )
  • Shipping weight
    690.0lbs. ( 312.98KG )
  • Shipping Height
    65.98inches ( 1676MM , 167.6CM )
  • Shipping Width
    85.0inches ( 2159MM , 215.9CM )
  • Shipping Depth
    55.0inches ( 1397MM , 139.7CM )

Environmental

  • Operating Temperature
    -4 - 122 °F ( -20 - 50 °C )
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Audible noise at 1 meter from surface of unit
    59.0dBA

Conformance

  • Approvals
    ETL
  • Standard warranty
    1 year (parts only)

General

  • Air Discharge Patterns
    Horizontal, Upflow
  • Air Flow
    5400.0CFM ( 2548.5lps )
  • Amp Draw In-Rush
    10.0A
  • Return Diameter
    0.88inches ( 22.0MM )
Design/Configuration
Title
Size
Updated On
PDF

Size

4538KB

Updated On

2023-10-04

InRow DX Gen 2 Technical Specifications
Title
Size
Updated On
Cooling Solutions, Chillers & Heat Rejection, Condensers