APC Rack PDU 9000 Switched, ZeroU, 30A, 120/208V, (16) 5-20R (7) C13/C15 (1) C19/C21

APC Rack PDU 9000 Switched, ZeroU, 30A, 120/208V, (16) 5-20R (7) C13/C15 (1) C19/C21

APDU9970

In stock
$1,400.00
Quantity

APDU9970 

APC Rack PDU 9000 Switched, ZeroU, 30A, 120/208V, (16) 5-20R (7) C13/C15 (1) C19/C21

With Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on/off outlet level power cycling and sequencing control.

Includes : Installation guide , Rack mounting brackets , Safety guide

  • Vertical Mounting Capabilities
    Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.

NetShelter Switched Rack PDUs Features & Benefits

  • Gigabit Ethernet Connectivity
    9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity.
  • Enhanced Cybersecurity
    9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind.
  • Network Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.
  • Multi-tier user access
    Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.
  • EcoStruxure IT Ready
    Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Outlet Level Grouping
    Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility.
  • Network Port Sharing
    Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series.
  • 1% Metering Accuracy
    Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.
  • C13/C15 and C19/C21 Hybrid Outlets
    Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.
  • 60C Operating Temperature
    All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).
  • High Retention Outlets
    With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.
  • Field-replaceable NMC
    Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.
  • Hydraulic Magnetic Circuit Breakers
    Provide increased availability by maintaining trip current over a wide temperature range.
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Product Distribution
Product Distribution

Brazil , Canada , Chile , Colombia , Peru , Taiwan , United States

Print Technical Specification

Output

  • Nominal Output Voltage
    120V , 208V
  • Overload Protection
    Yes
  • Maximum Total Current Draw
    24
  • Output Connections
    (1) C19/C21 (Battery Backup)
    (16) NEMA 5-20R (Battery Backup)
    (7) C13/C15 (Battery Backup)

Input

  • Nominal Input Voltage
    120V , 208V
  • Input frequency
    50/60 Hz
  • Input Connections
    NEMA L14-30P
  • Cord Length
    10.01ft ( 3.1meters )
  • Number of Power Cords
    1
  • Load Capacity
    4992VA
  • Maximum Input Current
    30A
  • Regulatory Derated Input Current (North America)
    24A

Physical

  • Maximum Height
    72.01inches ( 1829MM , 182.9CM )
  • Maximum Width
    2.2inches ( 56MM , 5.6CM )
  • Maximum Depth
    1.81inches ( 46MM , 4.6CM )
  • Net Weight
    20.79lbs. ( 9.43KG )
  • Shipping weight
    22.53lbs. ( 10.22KG )
  • Shipping Height
    80.35inches ( 2041MM , 204.1CM )
  • Shipping Width
    4.69inches ( 119MM , 11.92CM )
  • Shipping Depth
    6.48inches ( 165MM , 16.47CM )
  • Color
    Black

Environmental

  • Operating Temperature
    23 - 140 °F ( -5 - 60 °C )
  • Operating Relative Humidity
    5 - 95 %
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Storage Temperature
    -25 - 65 °C
  • Storage Relative Humidity
    5 - 95 %
  • Storage Elevation
    0 - 50000ft ( 0 - 15240meters )

Conformance

  • Approvals
    cUL listed, FCC part 15 class A, UL 62368-1
  • Standard warranty
    3 years repair or replace
Manuals and Warranties
Title
Size
Updated On
PDF

Size

1863KB

Updated On

2024-07-31

Firmware operating instructions
PDF

Size

2904KB

Updated On

2024-03-04

PDF

Size

188KB

Updated On

2022-07-07

Includes safety information and an illustration showing how to replace the display module for a rack power distribution unit.
Brochure
Title
Size
Updated On
PDF

Size

7901KB

Updated On

2024-02-22

Agency Approvals
Title
Size
Updated On
PDF

Size

686KB

Updated On

2022-10-07

Title
Size
Updated On
APC NetShelter Rack PDU 9000 Switched 0U 30A 120-208V 16-5-20R 7-C13 & 1-C19
CAD Source File
1654KB
2023-10-04

PDF
246KB
2023-10-04

Firmware Upgrades

EcoStruxure IT Expert
Part Number
Updated On

Part Number

SFTWES100-DIGI

Updated On

2002-01-15

Category

Sub-Category


Power Cord Kit (6 ea), Locking, C19 to C20, 1.8m

Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this exclusive easy-to-use cord retention method. While these cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled only when used with APC AP8000 series Rack PDUs or IT equipment with built-in locking receptacles. These locking connectors reduce the probability of accidentally disconnecting cords and dropping loads.

AP8716S
$203.00
Wired, Sensor, NetBotz, Temperature, 13 ft

Universal sensor that monitors temperature in your Data Center or Network Closet.

AP9335T
$93.00
Power Cord Kit (6 ea), Locking, C13 to C14, 1.8m, North America

Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this exclusive easy-to-use cord retention method. While these cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled only when used with APC AP8000 series Rack PDUs or IT equipment with built-in locking receptacles. These locking connectors reduce the probability of accidentally disconnecting cords and dropping loads.

AP8706S-NA
$136.00
APC NetShelter SX, Server Rack Enclosure, 42U, Black, 1991H x 600W x 1070D mm

Our high-performance IT Rack for data centers, server rooms & wiring closets

AR3100
$1,570.00
Subscription, Ecostruxure IT Expert, I year, 100 nodes, Remote monitoring and management of Data Centers.

EcoStruxure IT Expert monitors and protects your critical equipment, providing 24/7 visibility through live data, smart alarming, and data-driven insights on the health of your connected assets directly to your smartphone. EcoStruxure IT Expert synthesizes performance and alarming data into proactive recommendations, and enables secure, wherever-you-go visibility and control.

APC Temperature & Humidity Sensor

This Temperature & Humidity Sensor is a Universal sensor that monitors temperature and humidity in your Data Center or Network Closet. IT has an RJ-45 connector. The cord length is 3.9m.

AP9335TH
$150.00
NetShelter Zero U Accessory Mounting Bracket

Installs in various locations within the enclosure; for example, on the vertical mounting flanges and on the vertical 0U accessory channels. Provides mounting options for Rack PDUs and other small accessories.

AR7711
$90.00

Show results per page

Related Products, Accessories & Services

View all accessories and replacement batteries for this product