APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 100V to 120V, 24 NEMA 5-20R sockets

Share:

APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 100V to 120V, 24 NEMA 5-20R sockets

AP8632

In stock
$1,665.00
Quantity

AP8632 

APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 100V to 120V, 24 NEMA 5-20R sockets

APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by Struxureware for Data Centers using Data Center Expert and Data Center Operations with Capacity and Change modules.

Includes : Installation guide , Rack mounting brackets , Safety guide , Serial configuration cable

  • Vertical Mounting Capabilities
    Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.

NetShelter Metered-by-Outlet with Switching Rack PDU Features & Benefits

  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Remote Individual Outlet Control
    Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Metering-by-Outlet capability
    Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Outlet Power Sequencing
    Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
  • Network Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature)
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Product Distribution
Product Distribution

Canada , Chile , Colombia , Japan , Portugal , Taiwan , United States

Print Technical Specification

Output

  • Nominal Output Voltage
    100V , 120V
  • Overload Protection
    Yes
  • Output Connections
    (24) NEMA 5-20R (Battery Backup)

Input

  • Nominal Input Voltage
    100V , 120V
  • Input frequency
    50/60 Hz
  • Input Connections
    NEMA L5-30P
  • Cord Length
    9.84ft ( 3meters )
  • Acceptable Input Voltage
    100 - 120VAC
  • Number of Power Cords
    1
  • Load Capacity
    2880VA
  • Maximum Input Current
    30A
  • Regulatory Derated Input Current (North America)
    24A

Physical

  • Maximum Height
    72.01inches ( 1829MM , 182.9CM )
  • Maximum Width
    2.17inches ( 55MM , 5.5CM )
  • Maximum Depth
    2.01inches ( 51MM , 5.1CM )
  • Net Weight
    17.75lbs. ( 8.05KG )
  • Shipping weight
    22.33lbs. ( 10.13KG )
  • Shipping Height
    80.35inches ( 2041MM , 204.1CM )
  • Shipping Width
    4.69inches ( 119MM , 11.92CM )
  • Shipping Depth
    6.48inches ( 165MM , 16.47CM )
  • Color
    Black

Environmental

  • Operating Temperature
    23 - 140 °F ( -5 - 60 °C )
  • Operating Relative Humidity
    5 - 95 %
  • Operating Elevation
    0 - 10000ft ( 0 - 3048meters )
  • Storage Temperature
    -25 - 65 °C
  • Storage Relative Humidity
    5 - 95 %
  • Storage Elevation
    0 - 50000ft ( 0 - 15240meters )

Conformance

  • Approvals
    cUL listed, FCC part 15 class A, ICES-003, PSE, UL 60950-1, UL listed
  • Standard warranty
    2 years repair or replace
Manuals and Warranties
Title
Size
Updated On
PDF

Size

547KB

Updated On

2024-07-29

Release Notes for: AP7•••B and AP8••• series Rack Power Distribution Units and AP71••B Inline Current Meters
PDF

Size

1939KB

Updated On

2024-05-07

Provides the safety information for installation and operation of the Rack PDU.
PDF

Size

1689KB

Updated On

2024-02-07

Includes multi-language installation instructions and DHCP network information for MPO (managed per outlet AP86xx) Rack Power Distribution Units
PDF

Size

58KB

Updated On

2023-10-04

Release Notes for AP88XX Metered Rack PDUs and AP89xx/AP86xx Switched Rack PDUs for Application Module v6.4.0, APC OS (AOS) v6.4.0, and the APC PowerNet MIB v415
PDF

Size

274KB

Updated On

2022-02-01

Terminator installation instructions for Switched with Metering by Outlet Rack PDUs with CAN IN/OUT ports
PDF

Size

113KB

Updated On

2021-11-08

Release Notes for NetShelter Rack PDUs. AOS v704, rpdu2g v706,
Catalogs
Title
Size
Updated On
PDF

Size

7075KB

Updated On

2024-11-04

Brochure including Basic, Metered, Switched, and Metered by Outlet Rack PDUs product features and specifications
PDF

Size

48KB

Updated On

2023-10-04

Chart that specifies the APC Modular Power Distribution Units that support the installation of APC 208V & 415V Power Distribution Modules and specifies compatible APC Rack PDUs for each PDM.
Design/Configuration
Title
Size
Updated On
PDF

Size

1776KB

Updated On

2024-05-03

Features and Specifications
Agency Approvals
Title
Size
Updated On
PDF

Size

1067KB

Updated On

2024-02-21

PDF

Size

325KB

Updated On

2022-10-07

PDF

Size

2033KB

Updated On

2021-02-14

This approval is needed for sales of the PDU above in the United States and other NAM locations
Title
Size
Updated On
Power Distribution, Metered-by-Outlet with Switching Rack PDU

Category

Sub-Category


Wired, Sensor, NetBotz, Temperature, 13 ft

Universal sensor that monitors temperature in your Data Center or Network Closet.

AP9335T
$93.00
Warranty extension service pack, for accessories, 1yr, level 01

Get an extension of factory warranty coverage beyond the original factory warranty term for peace of mind and protection from failure

WBEXTWAR1YR-AC-04
$167.00
Cord Retention Bracket for AP8000 NEMA style PDUs Only

Cord retention brackets and vertical-mount bracket kits to complete rack power distribution solutions

NetShelter Zero U Accessory Mounting Bracket

Installs in various locations within the enclosure; for example, on the vertical mounting flanges and on the vertical 0U accessory channels. Provides mounting options for Rack PDUs and other small accessories.

AR7711
$90.00
AP6007A
$672.00
APC Temperature & Humidity Sensor

This Temperature & Humidity Sensor is a Universal sensor that monitors temperature and humidity in your Data Center or Network Closet. IT has an RJ-45 connector. The cord length is 3.9m.

AP9335TH
$150.00
Rack PDU Blue label kit (Quantity 10 units)

Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.

AP8000BLU
$64.00
AP6003A
$182.00
Rack PDU 2G, Metered-by-Outlet, ZeroU, 20A, 208V, (21) C13 & (3) C19

APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

AP8459NA3
$1,275.00
AP6002A
$231.00