More about the program Program rulesAPC NetShelter SX, Server Rack Enclosure, 45U, Shock Packaging, 2000 lbs, Black, 2124H x 600W x 1070D mm
APC NetShelter SX, Server Rack Enclosure, 45U, Shock Packaging, 2000 lbs, Black, 2124H x 600W x 1070D mm
NetShelter SX cabinet and packaging system designed to safely integrate, transport, unload and deploy up to 2000 lbs (907 kg) of IT equipment. The cabinet is paired with a shock absorbing pallet, unloading ramp, and impact resistant shell. The system has been engineered, tested and approved for secure shipment of fully converged systems such as being certified with Cisco® for pre-racking and shipping Cisco Unified Computing System (UCS).
Includes : Baying hardware , Key(s) , Keyed-alike doors and side panels , Leveling feet , Mounting hardware , Pre-installed casters , Side panels , User manual
United Arab Emirates , Antigua & Barbuda , Anguilla , Netherlands Antilles , Argentina , Austria , Australia , Barbados , Belgium , Bulgaria , Bermuda , Bolivia , Brazil , Bahamas , Belize , Canada , Switzerland , Chile , China , Colombia , Costa Rica , Serbia and Montenegro , Czechia , Germany , Denmark , Dominica , Dominican Republic , Algeria , Ecuador , Estonia , Egypt , Spain , Finland , France , United Kingdom , Grenada , Greece , Guatemala , Guyana , Hong Kong SAR China , Honduras , Croatia , Haiti , Hungary , Indonesia , Ireland , Israel , India , Italy , Jamaica , Japan , St. Kitts & Nevis , South Korea , Cayman Islands , Kazakhstan , St. Lucia , Lithuania , Latvia , Morocco , North Macedonia , Mexico , Malaysia , Nigeria , Nicaragua , Netherlands , Norway , New Zealand , Panama , Peru , Philippines , Poland , Puerto Rico , Portugal , Paraguay , Romania , Saudi Arabia , Sweden , Singapore , Slovenia , Slovakia , El Salvador , Thailand , Tunisia , Turkey , Trinidad & Tobago , Taiwan , Ukraine , United States , Uruguay , St. Vincent & Grenadines , Venezuela , U.S. Virgin Islands , Vietnam , South Africa
Size
2057KBUpdated On
2023-09-29Size
1982KBUpdated On
2023-09-21Size
81KBUpdated On
2022-02-01Size
32KBUpdated On
2024-02-22Size
250KBUpdated On
2024-02-22Size
1262KBUpdated On
2024-02-22Size
1285KBUpdated On
2024-02-22Size
5076KBUpdated On
2023-08-15Equipment Support Rails are ideal for mounting non-rack mountable equipment in a rack. These rails can support equipment measuring up to 16.75" (43cm) to 17.7" (45cm) wide and has a maximum weight of 200 lbs/91kg. The Support Rails attach to the side mounting holes of the vertical mounting rails.
High density, double-conversion on-line power protection with scalable runtime
With Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on/off outlet level power cycling and sequencing control.
Accessories to improve rack cooling efficiency by preventing air recirculation and reducing bypass airflow.
High density, double-conversion on-line power protection with scalable runtime
Highly available single phase UPS features redundant and scalable double-conversion on-line power protection
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Reliable rack power distribution
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
High density, double-conversion on-line power protection with scalable runtime