What does the 's' on the Power Meter Accuracy class 0.2s & 0.5s mean?

It refers to the accuracy of the meter. A 0.2s meter has a much higher accuracy as below. Since Accuracy depends on the load of the system, IEC/AS have developed different standards to define accuracy under different load conditions, known as “Accuracy Class” IEC/AS Standard 62053-11 covers...

How hot can circuit breakers get? What is the temperature of a molded case breaker?

Issue: What is the temperature of a molded case breaker? Product Line: Circuit Breakers Resolution: The acceptable operating temperature of a circuit breaker is defined by UL in the UL489 standard (June 2011), which is listed below. Terminations for standard rated breakers: UL 489 Paragraph...

What is the alternative for the XPSAL5110?

The closest alternative is XPSAC5121.

What is a current limiting circuit breaker?

Issue: What is a current limiting circuit breaker? Product Line: Molded Case Breaker, Powerpact Resolution: A current limiting circuit breaker is one that has been certified by UL to limit the let-through I^2t (I squared t) during a fault to not more than the I^2t available during a half cycle of...

What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

A9D33620 = SI (Super Immunised) A9D32620 = Type A (AC or pulsating DC) Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising. Type Si RCBO = With all the features of a Type A device, “Si” type...

What is the complete RJ45 connector pinout for ATV320?

The complete pinout, Pin 1 = CAN_H Pin 2 = CAN_L Pin 3 = CAN_GND Pin 4 = DI Modbus Signal Pin 5 = DO Modbus Signal Pin 6 - Not connected Pin 7 = VP, 10Vdc Pin 8 = Common The CANopen signals on the front port are deactivated if an option card is plugged in the drive (any option card connected).

How to Calculate the Required Capacity kVA Rating or Amperage Capacity for Single and Three Phase Transformers

Issue: Calculation of kVA capacity for a Single or Three Phase Transformer, based on Winding Voltage and Amperage information. Product Line: Low Voltage (LV) Transformers Learn more about DOE 2016 Energy Efficient Transformers by Schneider Electric Environment: Applies to all Single and Three...

How Can I Change a Wiser Mechanism from Zigbee to Bluetooth

To swap a Zigbee enabled switch to Bluetooth, press the switch 4 times and hold on the 4th press for 20+ seconds. When holding the button in at the 10 second mark a slow flashing red led should be visible, releasing at this point would be a factory reset. Continue to hold until the red led starts...

Show more
Popular Video FAQsPopular Videos
Show more
Learn more through our Generic Knowledge FAQsGeneral Knowledge
What are the effects of dV/dt on a Motor when using a VSD?

As there is an impedance mismatch at the termination of the motor cable to the motor, there will be a reflected wave which travels back along the motor cable causing overvoltage’s. Overvoltage’s on the motor terminals can cause both partial and corona discharge which eventually wears down the...

Apa alternatif replacement battery UPS SURT15KRMXLI jika APCRBC140 tidak ready stock?

Apa alternatif replacement battery UPS SURT15KRMXLI jika APCRBC140 tidak ready stock? ======================================================================= Untuk alternatifnya bisa menggunakan battery pack type SURT192XLBP sebanyak 2 sets, karena didalam 1 set SURT192XLBP terdapat 2 sets battery...

How to lodge warranty claims to Schneider Electric Australia for Schneider Electric Grid Tie or Battery Based Inverters?

Go to the SE Solar - Get Support website https://solar.schneider-electric.com/netsuite/ Fill in all mandatory fields, upload a scan of proof of purchase (customer invoice), supporting photos, single line diagrams showing all system components if applicable, detailed description of the issue and...

What is Power Factor Correction (PFC) - Does it help conserve energy?

Issue: What is Power Factor Correction (PFC) - Does it help conserve energy? Answer: Power Factor Correction (PFC) doesn't directly reduce the overall electric consumption of a device or system, but it does play a role in optimizing the efficiency of electrical systems, which can indirectly lead to...

How do I access the Tools Page in eDLT

Press and hold down the bottom left button, whilst continuing to hold then double press the top right button. Please note that access to the Tools Page can be disabled using C-Bus Toolkit software.

What is the difference between SQL Server server names and SQL Server instance names?

Numerous Schneider Electric Software use Microsoft SQL Server for logging and reporting of data. Examples include EcoStruxure Power Monitoring Expert, EcoStruxure Building Operations - Report Server, EcoStruxure Security Expert, DALI Buildings, Schedule Plus etc. SQL Server server names - refer to...

What is an Electrical "Ground Loop" - How does it affect my equipment?

Issue: What is an electrical "ground loop" and how does it affect my equipment? Environment: Ground loops can occur in any situation where multiple electrical devices are interconnected, especially when those devices are powered from different sources or located in different places with varying...

What is Modbus and How does it work?

What is Modbus? Modbus is a serial communication protocol developed by Modicon published by Modicon® in 1979 for use with its programmable logic controllers (PLCs). In simple terms, it is a method used for transmitting information over serial lines between electronic devices. The device...

Show more
move-arrow-top
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.
Your browser is out of date and has known security issues.

It also may not display all features of this website or other websites.

Please upgrade your browser to access all of the features of this website.

Latest version for Google Chrome, Mozilla Firefox or Microsoft Edgeis recommended for optimal functionality.