Please find attached modbus register list for Hexa series meters ( PM1125H,PM2105H,M6459H,DM6200H,EM6433H,EM6436H,PM1120H,EM6438H,PM1130H )
Issue When SQL Server is servicing requests from many clients, there is a strong possibility that conflicts will occur because different processes request access to the same resources at the same...
Issue Access the User Guide for EM6400 series meters, EM6430 meter, and EM6435 meter Product Line EM6400, EM6430, EM6435 Resolution All User Guides may be found at the following URL:...
Use the attachment to download window 10 supported PLC USB Driver version 3.18 IE28.
Kindly find the attachment below:
A static bypass switch automatically and instantaneously transfers the load to the mains electricity supply when there’s an internal fault or failure with the UPS system. It is a common...
Please refer attached modbus register list for EM6400 series meters.
Kindly refer attached check list for complaint registration of Schneider Electric LV/HV Electrical Distribution and Industrial Automation products.
The power Consumption in VA is Bus Current * Voltage And the Power dissipation is "lost" or wasted power, represented by the power converted to lower forms such as heat that are no longer...
This is the rms value of the current which the switchgear can carry in the closed position during a specified short time. Short time is generally 1 s, and sometimes 3 s.
This is the voltage that appears across the terminals of a circuit breaker pole after the current has been interrupted. The recovery voltage wave form varies according to the real circuit...
Steps for troubleshooting humming noise in ATV320: Check the noise reduction parameter 'nrd'. Try setting it to Yes and check. Check the parameter Switch Freq Type 'SFt'. Try setting...
To summarize: -Compartmented switchgear and control gear: Metal-enclosed switchgear and control gear assemblies with an external metal enclosure intended to be earthed and complete except for...
Allow customer to keep a service continuity in case of electrical tripping : no longer necessary to press the reset button to enable the closing after tripping. The reset button and SDE contact are...
This is a safety device and UL standard option, which automatically discharges the spring before the breaker is removed from the chassis. This is made thanks to the safety trip lever of the basic...
It is possible to increase distance between Harmony XB4/XB5R Transmitter and Receiver unit. There is no such limitation of the antennas that can installed. But you have to actually know, how much...

Support Centre
Download Centre
Please find attached modbus register list for Hexa series meters ( PM1125H,PM2105H,M6459H,DM6200H,EM6433H,EM6436H,PM1120H,EM6438H,PM1130H )
Issue When SQL Server is servicing requests from many clients, there is a strong possibility that conflicts will occur because different processes request access to the same resources at the same time. A conflict in which one process is waiting for another to release a resource is called a block....
Issue Access the User Guide for EM6400 series meters, EM6430 meter, and EM6435 meter Product Line EM6400, EM6430, EM6435 Resolution All User Guides may be found at the following URL:...
Use the attachment to download window 10 supported PLC USB Driver version 3.18 IE28.
Kindly find the attachment below:
A static bypass switch automatically and instantaneously transfers the load to the mains electricity supply when there’s an internal fault or failure with the UPS system. It is a common characteristic of an online UPS. In effect, running on bypasses the UPS circumvents (i.e., rectifier, batteries,...
Please refer attached modbus register list for EM6400 series meters.
Kindly refer attached check list for complaint registration of Schneider Electric LV/HV Electrical Distribution and Industrial Automation products.
The power Consumption in VA is Bus Current * Voltage And the Power dissipation is "lost" or wasted power, represented by the power converted to lower forms such as heat that are no longer useful in that system. In relation to a power supply the dissipated power is the difference between the input...
This is the rms value of the current which the switchgear can carry in the closed position during a specified short time. Short time is generally 1 s, and sometimes 3 s.
This is the voltage that appears across the terminals of a circuit breaker pole after the current has been interrupted. The recovery voltage wave form varies according to the real circuit configuration. A circuit breaker must be able to break a given current for all transient recovery voltages...
Steps for troubleshooting humming noise in ATV320: Check the noise reduction parameter 'nrd'. Try setting it to Yes and check. Check the parameter Switch Freq Type 'SFt'. Try setting it to HF2 and check. If these settings does not resolve then check the below points in the installation site: Ensure...
To summarize: -Compartmented switchgear and control gear: Metal-enclosed switchgear and control gear assemblies with an external metal enclosure intended to be earthed and complete except for external connections. e.g. SM6 switch cubicle. -Metal clad switchgear and control gear: Metal-enclosed...
Allow customer to keep a service continuity in case of electrical tripping : no longer necessary to press the reset button to enable the closing after tripping. The reset button and SDE contact are still indicating that a fault occurred, but the tripping bar is in operation position for immediate...
This is a safety device and UL standard option, which automatically discharges the spring before the breaker is removed from the chassis. This is made thanks to the safety trip lever of the basic frame, and additional feature operating the closing lever of the mechanism.
It is possible to increase distance between Harmony XB4/XB5R Transmitter and Receiver unit. There is no such limitation of the antennas that can installed. But you have to actually know, how much maximum distance will be required between transmitter and receiver unit/units for your application....
